Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors

Author: Saikat Sahoo†, Yoosun Kim†, Dongmin Go, Sejun Park, Jeongho Choo, Gyeongmo Kim, Cheonkyu Park, Giuk Lee

Corresponding author: Giuk Lee

Journal: Biomimetics

Published date: 2026.11
Link: https://www.mdpi.com/2313-7673/11/11/782

DOI: 10.3390/biomimetics11110782

This study examined whether human-in-the-loop (HITL) optimization, which personalizes exosuit assistance to each user, can be performed using only the sensors already built into the exosuit, without respirometry equipment. Conventional HITL optimization relies on bulky equipment to measure metabolic cost, and existing proxy measures either require additional sensors or have an unquantified relationship with metabolism. Building on their previous approach based on positive mechanical power (PMP), the researchers investigated whether stride time (ST), measured by the exosuit's thigh-mounted inertial sensors, better represents metabolic reduction.

Using grid-search data from three participants walking at 1 m/s on a 5° incline with a hip extension exosuit (six subject-day cases), stride time correlated with metabolic reduction numerically better than PMP (r = 0.63 ± 0.14 vs. 0.51 ± 0.37). A multi-variable cost function (MVCF) combining the two by multiple linear regression performed best (r = 0.68 ± 0.11) with the lowest mean absolute error, although the differences between cost functions were not statistically significant. When the MVCF was used as the objective of Bayesian HITL optimization in five participants, the optimized assistance reduced net metabolic rate by 13.3%, 7.5%, and 5.2% compared with the power-off, no-suit, and biomimetic conditions, respectively.

The researchers concluded that combining device-side mechanical power with human-side gait timing may provide an onboard-sensor cost function grounded in measured metabolic data. These are exploratory results from treadmill incline walking with a small number of participants, and further validation in other walking conditions is needed.

Funding information:

National Research Foundation of Korea (NRF) grants funded by the Korea government (MSIT)

  • Grant No. RS-2025-00555545
  • Grant No. RS-2025-02216282